electronics contract manufacturer

Bulletin 690 KG Relay Timer

Relay Timer Specification

Request Quote
KG Relay Description OP TDR Relay True Off Delay Voltage Sensor Recycle Relay

Input Current:

Idle (Action 2 and 3 only) = 4 ma
Operating = 2 VA
Control Switch: (Action 2 only) = 4 ma

Output Relay:

DPDT Contacts rated:
10 Amps resistive or 1/3 HP @ 120 VAC

Operating Parameters:

Repeat Accuracy:
   Fixed Conditions = ±3%, ± 1 cycle for AC
   units. Overall variation = ±10%
Input voltage range:
   ±10% @ 50 or 60 Hz for AC units
   ±10% @ 20% max. pp. ripple for DC units
Temperature range:
   -10º to 70º C operating
   -20º to 85º C storage
Reset time:
   Action 1 = 50 ms
   Action 2 and 3 = 150 ms
Initiate time (Control Switch):
   Action 2 = 50 ms

Size (less leads):

Termination:

2.1" Square x 1.8" High

1/4" Quick Connect Terminals