Input Current:
|
Idle (Action 2 & 3 only) = 4 ma.
Control Switch (Action 2 only) = 4ma.
|
|
Output Voltage:
|
On-state voltage drop:
Action 1 (AC) = 2.5 VRMS
Action 1 (DC) = 3.0 VDC
Action 2 & 3 (AC) = 2.0 VDC
Action 2 & 3 (DC) = 1.5 VDC
|
|
Output Current:
|
Maximum:
Action 1 = 100 ma.
Action 2 & 3 = 500 ma.
Minimum:
Action 1 (AC or DC) = 10 ma.
Action 2 & 3 (AC only) = 10 ma.
Leakage:
Action 1 (AC or DC) = 0.4 ma.
Action 2 & 3 (DC only) = 1 ma.
|
|
Operating Parameters:
|
Repeat Accuracy:
Fixed conditions = ±3%, ± 1 cycle for AC
units. Overall variation = ±10%
Input voltage range:
±20% for AC units
±20% @ 20% max. peak to peak ripple for
DC units
Temperature range:
-10 to +70 degress C operating
-20 to +85 degrees C storage
Reset time:
Action 1 = 50 ms.
Action 2 & 3 = 150 ms.
Initiate time (Control switch):
Action 2 = 50 ms.
|
|
Size (less leads):
|
Action 1 = 1.25"L x 0.6"W x 0.3" thick
Action 2 & 3 = 1.25"L x 1.0"W x 0.5"thick
|
|
Termination:
|
22 AWG solid tinned copper leads 1.75" Long
|