ICS

Bulletin KG Chassis Mount Series

KG Series Relay Timer

The KG series chassis mount relay timer is a self-contained delay unit that includes an on-board relay and timer module. The circuit board, with attached standoffs, can be mounted to a chassis in minutes. 1/4" quick-connect blade connectors provide the external wiring connections making installation simple and fast.
The KG relay timer is configured with either an adjustable or preset timer. A wide selection of input voltages and timing options is available.
Chassis Mount Relay Timer

• Standoffs for Chassis Mounting
• Heavy Duty Long Life Relay
• 1/4" Quick Connect Terminals
• On Board Timer Adjustment
• Timing from .1 Second to 300 Seconds
• Thick Film Hybrid Timer

Table 1. Part Number Selection
Timer Action
(1) On Delay
(2) Off Delay
(3) Interval Delay
Timing Range
Standard:
(1) .1 to 10 second
(2) .5 to 5 second
(7) 3 to 30 second
(4) 30 to 300 sec.
Nonstandard:
(5) 1 to 10 second
(3) 5 to 50 second
(8) 6 to 60 second
(6) 12 to 120 sec.
(0) *Special Time

*Customer defined
Input Voltage (AC or DC)
Standard:
(2) 24 VAC
(1) 120 VAC
(8) 12 VDC
(4) 24 VDC
Nonstandard:
(7) 12 VAC
(5) 240 VAC
(6) 48 VDC
(3) 110 VDC
KG Relay Order Code Example
Interval Delay:
KG 3 7 1
(3) Interval Delay
(7) 3 to 30 sec.
(1) 120 Volt AC
Relay Timer Order Code Diagram
KG Relay Order Code Example
Off Delay:
KG 2 3 8
(2) Off Delay
(3) 5 to 50 sec.
(8) 12 Volt DC
Relay Timer Order Code Diagram
Options. Fixed and special time delay ranges from .05 second to 10 hour.


time delay relay schematic


off delay relay wiring diagram

Wiring Diagrams: Top view of modules.


Table 2. Specifications
Input Current
Idle (Actions 2 and 3 only) = 4 ma.
Operating = 2 VA.
Control Switch (Action 2 only) = 4 ma.
Output Relay
DPDT Contacts Rated:
10 Amps resistive or 1/3 HP @ 120 VAC
Operating Parameters
Repeat Accuracy:
Fixed Conditions = ±3%, ±1 cycle for AC units.
Overall variation = ±10%

Input voltage range:
±10% for AC units
±10% @ 20% max. pp. ripple for DC units

Temperature range:
-10º to 70º C operating
-20º to 85º C storage

Reset time:
Action 1 = 50 ms.
Actions 2 and 3 = 150 ms.

Initiate time (Control Switch):
Action 2 = 50 ms.
Size
2.1" Square x 1.8" High
Termination
1/4" Quick Connect Terminals
footer
Contact ICSAmerican Flag

American Manufacturer

Product Links

...Relays...
True Off Delay
Voltage Sensor
Compressor Delay Relay
Recycle Timer Relay
Cube Relay
...Timers...
Timing Actions
KA Series Microtimer
KD Repeat Cycle Timer
KT6 Recycle Timer
KH2 Off Delay Timer
KH1 On Delay Timer
KM Series Micro Timer
Wiring Examples
...Site Links...
ICS Home
Time Delay Catalog
Contacts
Support
Sitemap